D. Vent Diagrams

WARNING

1. Top Vent - Horizontal Termination

One Elbow

Two Elbows

NOTE: When venting with one elbow, a
straight section of venting (3 ft. minimum)
MUST be attached directly to starting col-
lars on unit.

NOTE:

V

1

MUST be a

minimum of 3 feet.

V

1

Minimum

H

1

Maximum

3 ft.

0.9 m

2 ft.

0.6 m

4 ft.

1.2 m

4 ft.

1.2 m

5 ft.

1.5 m

6 ft.

1.8 m

12 ft.

3.7m

20 ft.

6.1 m

V

1

+ H

1

= 40 ft. (12.2 m) Maximum

H

1

= 20 ft. (6.1 m) Maximum

NOTE: The fi rst elbow used MUST always
be DVP90ST.

Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.

NOTE: The first elbow used
MUST always be DVP90ST.

V

1

Minimum

H

1

+ H

2

Maximum

3 ft.

0.9 m

2 ft.

0.6 m

4 ft.

1.2 m

4 ft.

1.2 m

5 ft.

1.5 m

6 ft.

1.8 m

12 ft.

3.7 m

20 ft.

6.1 m

V

1

+ H

1

+ H

2

= 40 ft. (12.2 m) Maximum

H

1

+ H

2

= 20 ft. (6.1 m) Maximum