Caution, Warning – Hearth and Home Technologies Bravo User Manual

Page 29

Advertising
background image

Hearth & Home Technologies, Inc. • Bravo, Aztec • InD • 703-900 Rev. N • 8/06

29

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.
• Replace damaged wire with type 105

O

C

rated wire.

• Wire must have high temperature insulation.

WARNING

Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram

NEUTRAL

GROUND

REMOTE

CONTROL HOT

VALVE

BROWN

BROWN

ORANGE

GREEN

BLACK

BLACK (SENSOR)

BLACK

GROUNDTO

FIREPLACE

CHASSIS

PILOT ASSEMB

LY

AND VALVE ASSEMBLY

MUST BE GROUNDED

(COMMON GROUND

WITH FIREPLACE

CHASSIS)

PLUG-IN

3V TRANSFORMER

IGNITION
MODULE

(3V)

I

S

2045-024

2012-206

BLACK (IGNITO

R )

WA

L L SWITCH

TRANSFORMER

3 V

LOW VOLTA

G E

SEE NOTE 1

LOW VOLTA

G E

SEE NOTE 1

IGNITOR

MODULE

3V

FAN OUTLET RECEPTACLE

(NO FAN OPTION)

SPARK TO

PILOT IGNITOR

NOTE 1: Ignition module, valve, pilot and wall switch
operate on 3 volts. 120 VAC is required at junction box
unless equipped with battery back-up.

BLACK (IGNITOR)

3V

PILOT ASSEMBLY

AND VALVE ASSEMBLY

3V

WALL SWITCH

LOW VOLTAGE

SEE NOTE 1

LOW VOLTAGE

SEE NOTE 1

Advertising
This manual is related to the following products: