Installing flue components – Hearth and Home Technologies SL-550TRSI-AUE User Manual

Page 17

Advertising
background image

17

Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06

Figure 17.

WARNING: FAILURE TO REMOVE
INSULATION IN THE SET OF COL-
LARS YOU ARE USING COULD
CAUSE A FIRE.

WARNING: THE REAR FLUE COL-
LAR SEAL CAP MUST REMAIN AT-
TACHED TO THE REAR FLUE COL-
LARS IF THE FLUE SYSTEM IS AT-
TACHED TO THE TOP STARTING
COLLARS. SEE FIGURE 17.

WARNING: YOU MUST LEAV E
THE INSULATION IN PLACE IN
THE SET OF COLLARS YOU ARE
NOT USING.

FLUEING OUT REAR

FLUEING OUT TOP

Installing Flue Components

After determining which set of starting collars will be
used (top or rear), follow flueing instructions
accordingly.

Flueing Out the Rear Flue
Remove the rear collar seal cap by cutting the
strap at each end (see Figure 17).

Next, remove the insulation from the rear flue, pull
the heat shield out from outside of the heater.

WARNING: THE TOP FLUE COLLAR
SEAL CAP MUST REMAIN ATTACHED

TO THE TOP FLUE COLLAR IF THE FLUE
SYSTEM IS ATTACHED TO THE REAR
STARTING COLLARS. SEE FIGURE 17.

Flueing Out the Top Flue

Remove the top collar cover plate. Remove the
seal cap and both pieces of insulation in the top
collars (see Figure 17). Remove the heat shield
inside the top collars from the outside of the
heater.

!

!

!

!

Insert screwdriver

or similar object

here to remove cap.

CUT

HERE

HEAT

SHIELD

DISCARD

INSULATION

and

HEAT SHIELD

SEAL

CAP

SEAL

CAP

HEAT

SHIELD

INSULATION,

DISCARD

BOTH

PIECES and

HEAT SHIELD

Advertising