OM-952 Page 11

5-3. Replacing Liner O-Ring (Continued)

8 mm

Push liner toward gun. If necessary,

twist cable to ease installation.

Guide liner into head tube. Continue

to push liner until it exits end of

head tube.

Lower top portion of handle onto

bottom of handle. Slide locking

ring over rear of handle, and

secure with by twisting ring

clockwise 1/4 turn.

Slide top portion of handle over

head tube.

Be sure that cable is straight.

Tighten liner setscrew with

allen wrench. Cut liner so

that 3/4 in (19 mm) sticks out

of head tube.

3/4 in (19 mm)

Reassemble gun by placing

head tube into bottom section of

handle.

Thread welding wire through

gun (see Section 3-4). Reinstall

adapter, contact tip, and nozzle.

Reinstall cover onto wire

drive assembly, and secure

with screws (3).

2 mm

Insert retaining nut into liner, and adjust liner stickout as

shown. Tighten retaining nut. Reinstall cable end into drive

housing with retaining grooves inserted into the two retaining

ribs. Be sure to position gas hose up. Position liner in groove

so that end is flush with back of groove, adjust if necessary

13/16 in

(21 mm)

8 mm