Connectors, Base backplane communications – Fortinet 5003 User Manual

Page 20

Advertising
background image

FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide

20

01-30000-85717-20081205

Base backplane communications

FortiSwitch-5003 system

Connectors

Table 9

lists and describes the FortiSwitch-5003 front panel connectors.

Base backplane communications

This section provides a brief introduction to using FortiSwitch-5003 boards for
base backplane communication.

FortiSwitch-5003 boards installed in a FortiGate-5140 or FortiGate-5050 chassis
in slot 1 or slot 2 provide base backplane switching for all of the FortiGate-5000
series boards installed in chassis slots 3 and above. Base backplane switching
can be used for HA heartbeat communication and for data communication
between FortiGate-5000 series boards.

The FortiGate-5000 series boards can all be installed in the same chassis, or you
can use the FortiSwitch-5003 front panel ZRE interfaces for base backplane
communication among multiple FortiGate-5140 and FortiGate-5050 chassis. The
communication can be among a collection of the same chassis (for example,
multiple FortiGate-5050 chassis) or among a mixture of FortiGate-5140 and
FortiGate-5050 chassis. In most cases you would connect the same base
backplane interfaces together, but you can also use the FortiSwitch-5003 front
panel ZRE interfaces for connections between base backplane interface 1 and
base backplane interface 2. Again these connections can be within the same
chassis or among multiple chassis.

A FortiSwitch-5003 board in slot 1 provides communications on base backplane
interface 1. The FortiGate-5001SX and the FortiGate-5001FA2 boards
communicate with base backplane interface 1 using the interface named port9.
The FortiGate-5005FA2 board communicates with base backplane interface 1
using the interface named base1.

A FortiSwitch-5003 board in slot 2 provides communications on base backplane
interface 2. The FortiGate-5001SX and the FortiGate-5001FA2 boards
communicate with base backplane interface 2 using the interface named port10.
The FortiGate-5005FA2 board communicates with base backplane interface 2
using the interface named base2.

Table 9: FortiSwitch-5003 connectors

Connector Type Speed

Protocol

Description

ETH0

RJ-45 100Base-T Ethernet

Front panel out of band management

interface. A second out of band

management interface, ETH1, connects to

the shelf managers. Neither of the out of

band management interfaces are used.

CONSOLE RJ-45 9600 bps

RS-232

serial

Serial connection to the command line

interface.

ZRE0,
ZRE1,
ZRE2

RJ-45 10/100/1000

Base-T

Ethernet

Redundant connections to another

FortiSwitch-5003 board in an different

FortiGate-5140 or FortiGate-5050 chassis.

Use these interfaces for base backplane

interface connections between

FortiGate-5000 series chassis.

Advertising