1.3 Power Requirements

C141-E192-01EN

1-7

(4) Current Requirements and Power Dissipation

Table 1.3 lists the current and power dissipation (typical).

Table 1.3 Current and power dissipation

Typical RMS Current

Typical Power (*3)

MHT Series

MHT Series

Spin up (*1)

0.9 A

4.5 W

Idle

130 mA

0.65 W

R/W (on track) (*2)

Read 400 mA / Write 420mA

Read 2.0 W / Write 2.1 W

Seek (*5)

460 mA

2.3 W

Standby

50 mA

0.25 W

Sleep

20 mA

0.1 W

Energy
Efficiency (*4)

0.008 W/GB

(rank E / MHT2080AT)

0.011 W/GB

(rank E / MHT2060AT)

0.011 W/GB

(rank E / MHT2040AT)

0.022 W/GB

(rank D / MHT2030AT)

0.022 W/GB

(rank D / MHT2020AT)

*1

Current at starting spindle motor.

*2

Current and power level when the operation (command) that accompanies a
transfer of 63 sectors is executed 3 times in 100 ms

*3

Power requirements reflect nominal values for +5 V power.

*4

Energy efficiency based on the Law concerning the Rational Use of Energy
indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)

*5

The seek average current is specified based on three operations per 100
msec.

(5) Current fluctuation (Typ.) at +5 V when power is turned on