Pre-inStALLAtiOn

LOCATION AND SpACE

REqUIREMENTS

Determine the safest and most efficient loca-

tion for your direct vent fireplace. Make sure

that rafters and wall studs are not in the way of

the venting system. Choose a location where

the heat output is not affected by drafts, air

conditioning ducts, windows or doors. Figure

2 shows some common locations. Be aware

of all restrictions and precautions before

deciding the exact location for your fireplace

and termination cap.
When deciding the location of your fireplace,

follow these rules:
• Do not connect this fireplace venting to a

chimney flue serving a separate solid-fuel

burning fireplace or appliance.

• Due to high temperatures, do not locate this

fireplace in high traffic areas, windy or drafty

areas or near furniture or draperies.

• Proper clearances must be maintained.
• If your fireplace is to be installed directly on

carpeting, vinyl tile or any combustible mate-

rial other than wood, it must be installed on a

metal or wood panel extending the full width

and depth of the fireplace (see Figure 3).

• Your fireplace is designed to be used in

zero clearance installations. Wall or fram-

ing material can be placed directly against

any exterior surface on back, sides or top

of your fireplace, except where standoff

spacers are integrally attached. If standoff

spacers are attached to your fireplace,

these spacers can be placed directly

against wall or framing material. See fram-

ing details, page 7.

• When locating termination cap, it is impor-

tant to observe the minimum clearances

shown in Figure 7, page 8.

• If recessing into a wall, you can avoid extra

framing by positioning your fireplace against

an already existing framing member.

• Do not recess termination cap into a wall

or siding.

• You may paint the termination cap with

450º F (232º C) heat-resistant paint to

coordinate with the exterior finish.

• There must not be any obstruction such as

bushes, garden sheds, fences, decks or

utility buildings within 24" from the front of

the termination cap and the front of outside

air vent.

• Do not locate termination cap and outside

air vent where excessive snow or ice build

up may occur. Be sure to clear vent ter-

mination area after snow falls to prevent

accidental blockage of venting system.

When using snow blowers, do not direct

snow towards vent termination area.

29" (36")

34

3

/

4

" (42")

21" (36")
25" (42")

41

1

/

4

" (36")

48

1

/

4

" (42")

11

7

/

8

" (36")

13

5

/

8

" (42")