I. pin descriptions – Finisar FWDM-1629-XX User Manual

Page 3

Advertising
background image

FWDM-1629-XX DWDM SFP Preliminary Product Specification – February 2005

F i n i s a r

Finisar Corporation

PRELIMINARY and Confidential

Page 3

Rev C, February 2005


I.

Pin Descriptions

Pin

Symbol

Name/Description

Ref.

1

V

EET

Transmitter Ground (Common with Receiver Ground)

1

2

T

FAULT

Transmitter Fault

3

T

DIS

Transmitter Disable. Laser output disabled on high or open

2

4

MOD_DEF(2)

Module Definition 2. Data line for Serial ID

3

5

MOD_DEF(1)

Module Definition 1. Clock line for Serial ID

3

6

MOD_DEF(0)

Module Definition 0. Grounded within the module

3

7

Rate Select

No connection required

4

8

LOS

Loss of Signal indication. Logic 0 indicates normal operation

5

9

V

EER

Receiver Ground (Common with Transmitter Ground)

1

10

V

EER

Receiver Ground (Common with Transmitter Ground)

1

11

V

EER

Receiver Ground (Common with Transmitter Ground)

1

12

RD-

Receiver Inverted DATA out. AC Coupled

13

RD+

Receiver Non-inverted DATA out. AC Coupled

14

V

EER

Receiver Ground (Common with Transmitter Ground)

1

15

V

CCR

Receiver Power Supply

16

V

CCT

Transmitter Power Supply

17

V

EET

Transmitter Ground (Common with Receiver Ground)

1

18

TD+

Transmitter Non-Inverted DATA in. 100 ohm termination between TD+
and TD-, AC Coupled thereafter

19

TD-

Transmitter Inverted DATA in. See TD+

20

V

EET

Transmitter Ground (Common with Receiver Ground)

1


Notes:
1. Circuit ground is internally isolated from chassis ground.
2. Laser output disabled on T

DIS

>2.0V or open, enabled on T

DIS

<0.8V.

3. Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 5.5V.

MOD_DEF(0) pulls line low to indicate module is plugged in.

4. Finisar 2x receiver achieves simultaneous 1x and 2x operation without active control.
5. LOS is open collector output. Should be pulled up with 4.7k – 10kohms on host board to a voltage

between 2.0V and 5.5V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.

VeeT

VeeT

VeeR

VeeR

TD-

TD+

RD+

RD-

VccT

VccR

VeeT

VeeR

TXFault

MOD-DEF(2)

MOD-DEF(1)

MOD-DEF(0)

Rate Select

LOS

1

2

3

4

5

6

7

8

9

10

20

19

18

17

16

15

14

13

12

11

Towards

ASIC

Towards

Bezel

TX Disable

VeeR