HEATED LANDING ZONE

CHAPTER 6: OPERATOR TROUBLESHOOTING



8

Symptom Possible

Cause

No computer display; no flow from
air tower

• No

power

• Circuit breaker out

• Low

voltage

• Bad

fuse

• Bad

transformer

• Hi-limit

out

No flow from air tower

• Bad latching relay

After 20 minutes of operation
computer display shows PROB

• RTD probe has failed. Isolate failed component

by checking temperature of air and heater plate
with the temperature display keys on the
computer. The plate temperature should be
within ± 15°F of setpoint. The air heat should be
within ± 25°F of setpoint. If both temperatures are
good, the computer is likely bad.

After 20 minutes of operation
computer display shows HI

• Plate heater, plate heater relay or RTD are faulty.

After 20 minutes of operation
computer display shows LO

• Air heater, air heater relay or RTD are faulty