Furuno CH-37 User Manual

Page 87

Advertising
background image

SP - 2

(6) Horizontal Range

12 steps during 30 m to 1600 m

(7) Vertical Range

12 steps during 10 m to 800 m

(8) E/S Range*

5 steps during 10 m to 800 m

(9) E/S Shift*

1000 m max.

(10) Offcenter

4 point at Expand mode, according to the train setting

2 point at Slice mode, according to the tilt setting

(11) TVG

Level(100 dB max.), Range(1000 m max.)

(12) Clutter

Variable, Hue control

(13) Elimination Interference

Correlation with before data

(14) Audio Monitor

2 W, 4 ohms using external speaker SC-05WR(option)

*: Optional external E/S interface is required.

3. TRANSCEIVER

(1) Frequency

60/162 kHz selected by internal settings

(2) Output Power

0.8 kW(60 kHz), 1.5 kW(162 kHz)

(3) Beamwidth

-6 dB,

(4) Pulselength

0.2 to 10.6 ms, varied according to the range in use

(selected on the Menu)

4. HULL UNIT

(1) Train Step

45° step by fast scan mode or 6° step by normal mode

(2) Tilting

Horizontal mode

Tilt Range: +5° to 90°, Tilt Step: 1° step

Vertical Fan Mode

Tilt Range: 0° to +180°, Tilt Step: 6°(fast scan) or 3°(normal)

(3) Transducer Travel

400 mm

(4) Raise/Lower Time

10 sec approx. (24/32 VDC)

(5) Allowable Ship’s Speed

18 knots or less

(15 knots during raise/lower operation)

5. POWER SUPPLY AND CONSUMPTION

(1) Display Unit

24/32 VDC (20 to 41.6VDC), 140 W approx. or

100/110/200/220 VAC, 50/60 Hz , 1

(2) Transceiver Unit

24/32 VDC (20 to 40 VDC), 50 W approx. or

100/110/200/220 VAC, 50/60 Hz , 1

(3) Hull Unit

24/32VDC, 50 W approx. (150 W while traveling)

AC spec. set requires rectifier RU-1746B-2

Advertising