Maintenance, troubleshooting, 1 maintenance, Warning – Furuno 1623 User Manual

Page 26: Notice

Advertising
background image

18

2. MAINTENANCE, TROUBLESHOOTING

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment.

Only qualified personnel
should work inside the
equipment.

NOTICE

Do not apply paint, anti-corrosive sealant
or contact spray to coating or plastic
parts of the equipment.

Those items contain organic solvents that
can damage coating and plastic parts,
especially plastic connectors.

2.1 Maintenance

Regular maintenance is important for good performance. A maintenance program should be
established and should at least include the items listed in the table below.

Maintenance program

Period Item

Check

point

Action

Fixing bolts for
antenna unit

Check for corrosion and if
tightly fastened.

Replace corroded bolts. Coat new
bolts with anticorrosive sealant.

Antenna unit
cleanliness

Check for foreign material.
(Foreign material on the
antenna unit can cause a
considerable drop in
sensitivity.)

Clean the antenna unit with a
freshwater-moistened cloth.
Alcohol may be used. Do not use
commercial cleaners to clean the
antenna unit; they can remove
paint and markings or deform the
equipment.

Antenna unit
cover

Check for cracks. Permanent
damage to the unit’s circuitry
will result if water leaks inside.

If a crack is found, it should be
temporarily repaired by using a
small amount of sealing compound
or adhesive. The unit should then
be brought to your dealer for
permanent repairs.

3 to 6
months

Display unit
case, LCD

The LCD will, in time,
accumulate a coating of dust
which tends to dim the picture.

Wipe the LCD carefully to prevent
scratching, using tissue paper and
an LCD cleaner. To remove dirt or
salt deposits, use an LCD cleaner,
wiping slowly with tissue paper so
as to dissolve the dirt or salt.
Change paper frequently so the
salt or dirt will not scratch the LCD.
Do not use solvents such as
thinner, acetone or benzene for
cleaning; they can remove paint
and marks or deform the
equipment.

6 months
to 1 year

Display unit
connectors

Check for tight connection and
corrosion.

If corroded, ask your dealer about
replacement.

Advertising