5 device operation – First Virtual Communications PS1010-3A User Manual

Page 5

Advertising
background image

IBBI Electronics

5

Voltmeter range

0-35V

5 Device

operation

5.1 Setting output voltage

• Put VM/Vout switch [(10)] to Vout position

• Put C/V switch [(8)] to V position

• Volt LED indicator will light up [(4)]
• [(3)] will display “U” for Volt

• Adjust the voltage controller [(5)] to get the

required value.

• The value will be displayed on [(2)] with one

decimal place

Note: Make sure to keep reasonable current limiting
value before setting output voltage so that current
control (CC) will not take over.

5.2 Setting current limit

• Press and hold C-SET button [(7)].

• Then display[(2)] will show the present current

limit in Amperes.

• [(3)] will display “A” for Current
• Now rotate the current controller knob [(6)]

while looking at the display. Stop when the
desired value appears.

Note: The output voltage will be automatically be
controlled if the external device tries to drag current
more than the set limit.

5.3 Viewing actual current flow

• Power up the DUT with PS1010-3A