Operation

The temperature controller and probe indicate when the refrigeration system is required to turn on and off.

The refrigeration system removes heat from the cabinet interior and rejects it to the surrounding room air. When the
cabinet interior temperature reaches +1.5 C above the controller set point, the probe signals the controller to turn
the refrigeration system on. The normally open controller contacts close and energize the condenser fan motor and
compressor. The compressor uses a current-style starting relay and a starting capacitor to start the compressor
motor.

When the cabinet interior temperature falls to the set point, the probe signals the controller to turn the refrigeration
system off. The controller contacts reopen, which de-energizes the condenser fan motor and the compressor. The
evaporator fan motor runs continuously.

Any accumulated frost on the evaporator coils melts during the off cycle. The condensate drains to a drain pan
mounted alongside the condensing unit. The heat from the condensing unit evaporates any condensate in the
drain pan.

Temperature control

The temperature control system is preset by the factory to maintain a cabinet temperature of +3.5 C to +5 C
(+38 F to +41 F). If desired, the cut-out temperature can be raised as high as +6°C by following the instructions
on page 5 for changing the temperature set point. The +1.5 C cut-out differential will be maintained regardless of
the controller set point.

Defrosting

REF5-BB Series undercounter refrigerators do not require manual defrosting. The unit cooler defrosts automatically
when the condensing unit is in the OFF cycle.

Cleaning

Interior – Using a sponge or soft cloth, clean unit with a non-abrasive, non-chlorinated, all-purpose detergent.

Exterior – Wipe exterior with a soft cloth in the direction of grain as needed. Stainless steel polish may be used to

enhance the fi nish of the unit.

Annual cleaning

Removal of dust and other particulates from air intake areas and the condenser is important for proper operation.
Some environments with large amounts of dust may require more frequent cleaning.

1. Disconnect power to unit by turning switch on the lower front

panel to the OFF position, switching circuit breaker to OFF
position, and removing power cord from receptacle.

2. Remove lower front panel (Fig. 7.1).

Note: Front louvered panel may be completely removed for

easier cleaning by disconnecting the controller wiring plugs from
the freezer.

3. Remove drain pan (Fig. 7.2).
4. Clean drain pan with a non-abrasive, non-chlorinated all-purpose

detergent.

5. Reinstall drain pan.

6. Use a vacuum cleaner with brush attachment to clean condenser

through lower front panel and compressor motor and related
parts through lower rear panel.

7. Reinstall lower front panel.