3 transducer – Furuno FE-700 User Manual

Page 10

Advertising
background image

4

F type

Flush Mount Kit (F): OP02-79-1 (001-229-290)

OP02-79-2 (001-229-300)

OP02-79-3 (001-229-310)

No. Name

Type

Code

no.

Qty Remarks

100-279-270 OP02-79-1:N3.0
100-279-280 OP02-79-2:2.5GY5/1.5

1

Cosmetic
panel

02-129-1041-0

100-279-290

1

OP02-79-3:7.5GY7/2

2 Hex

bolt M6x12

000-162-897-1
0

4

3

Spring
washer

M6

000-158-855-1
0

4

1. Prepare a cutout in the mounting location whose dimensions are 210 (W) x 194 (H) mm.

2. Attach the cosmetic panel (02-129-1041-0) to the display unit with four hex bolts (M6x12)

and four spring washers (M6).

3. Fix the display unit to the mounting location with four tapping screws (5x20).

S type

Flush Mount Kit (S):

OP02-80 (001-229-320)

No. Name

Type

Code

no.

Qty

Remarks

1 Fixing

plate

02-129-1045-0

100-279-300 2

2 Wing

bolt

M4x30

000-804-799 6

3 Hex

bolt

M6x12

000-162-897-1
0

4

4

Spring
washer

M6

000-158-855-1
0

4

5 Wing

nut

M4

000-863-306 6

1. Prepare a cutout in the mounting location whose dimensions are 194 x 194 mm.

2. Insert the display unit to the cutout.

3. Attach two fixing plates (02-129-1045-0) to the display unit with four

hex bolts (M6x12) and spring four washers (M6).

4. Screw six wing bolts (M4x30) to wing nuts (M4).

5. Fasten the display unit with six wing bolts and nuts.

1.3 Transducer

The installation of the transducer and the tank should be accomplished by a dockyard referring
to the installation drawings at the back of this manual. An example of transducer installation
method is also shown in paragraph 1.3.2.

Note: Discussions should take place and agreement reached with the dockyard for sufficient

reinforcement and watertightness of the hull to comply with the regulations concerned.

Advertising