CT16 SERIES TOASTER

SERVICE AND PARTS MANUAL

CHAPTER 1: SERVICE PROCEDURES

Upper

Compression

Adjustment

Knobs

Lower

Compression

Adjustment

Knobs

Bun Guide for Heel

and Crown Slots

Heated Holding Tray

LOWER

SETPOINT

BUTTON

ON/OFF

BUTTON

LED

DISPLAY

RAISE

SETPOINT

BUTTON

DISPLAY

TEMPERATURE

BUTTON

REDY

1.1 CT16 Toaster Functional Description

The CT16 Toaster is designed to produce fresh, uniformly toasted buns on an "as needed” basis. The
countertop-mounted unit consists of a cabinet, a computer, a heating element and a pair of conveyor
assemblies.

When the unit is turned on, an electrical heating element (called a platen) is energized. The platen
heats up to a programmed temperature referred to as the setpoint. At the same time, both conveyor
assemblies are activated. When a bun is placed into one of the slots at the top of the cabinet, the
conveyor belts gently carry it through the unit, with the cut face of the bun passing over the heated
platen. As the bun passes over the platen, it is toasted. At the end of the process, the bun is deposited
onto a holding tray. The computer allows the operator to adjust the setpoint to obtain desired toasting
characteristics. Compression adjustment knobs also allow the operator to adjust the compression of
heels and crowns as they pass through the toaster.

1.2 Power Requirements

ALL ELECTRICALLY OPERATED APPLIANCES MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES, OR

IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE (ANSI/NFPA NO. 70-1990) OR THE

CORRESPONDING NATIONAL CODE OF THE COUNTRY IN WHICH INSTALLED.

THIS APPLIANCE IS EQUIPPED WITH A GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE

PLUGGED INTO A PROPERLY GROUNDED RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG!

• Voltage: 200VAC, 208VAC, or 240VAC, depending on model ordered

• Frequency: 60 Hz (non-CE )or 50 Hz (CE and Australian models)

• Phase: Single

• Service: 20 Amp