Frymaster CT16 Series User Manual

Page 6

Advertising
background image

1-4

e. Rotate the tray stabilizer latch upward and, while supporting the conveyor assembly, remove the

hex-head screw securing the top of the assembly from the outside (conveyor side) of the
component housing and carefully pull the assembly away from the housing.

Step 11b - Remove the drive pulley.

Step 11c - Remove
these five flange nuts
and the idler assembly.

Step 11d - Remove these
two hex head screws.

Step 11e - Remove the last screw and pull

the conveyor away from the housing.

f. Reinstall the conveyor assembly by reversing the steps performed, being sure to reattach the

two ground wires with the lower of the two hex head screws removed in Step 11d.

Replacing the High-Limit Thermostat or Heater Probe

(See illustration on following page.)

1. Turn off and unplug the unit, and remove toasting conveyor in accordance with the instructions on

Pages 18-19.

2. To replace the high-limit thermostat, remove the platen tray brace to expose the thermostat and

remove the screws securing it in place.

3. To replace the heater probe, remove the plug over the probe to expose the component. Remove

the screw securing the probe retainer and remove the probe.

Advertising