8 iec 61162-1 data sentences – Furuno Ls4100 User Manual

Page 41

Advertising
background image

35

Water temp/speed sensor

Connect the optional water temp/speed
sensor to the XDR connector with the
optional converter connector (Type
02S4147) as shown below.

Tape connectors with
vulcaninzing tape
and then vinyl tape
to waterproof them.
Bind tape ends with
cable ties to prevent
tape from unraveling.

Connect to XDR port
at rear of display unit

MJ-A10SPF

MJ-A10SRMD

MJ-A6SRMD

From
transducer

From
sensor

Connection of converter

connector 02S4147

4.8 IEC 61162-1 Data

Sentences

The tables below show the data
sentences which can be input to and
output from the LS-4100. The
transmission speed for both input and
output is 4800 bps. Data is output at
two-second intervals.

Input data sentences

Sentence Meaning

BWC

Bearing and distance to
waypoint

GGA

Global positioning system
(GPS) fix data

GLL Geographic

position

-

latitude/longitude

HDG

Heading, deviation and variation

HDT Heading,

true

MDA Atmospheric

pressure

MTW Water

temperature

Input data sentences (con’t)

Sentence Meaning

MWV Wind

speed

and

angle

RMA Recommended

minimum specific

LORAN-C data

RMB Recommended

minimum navigation

information

RMC Recommended

minimum specific

GPS/TRANSIT data

VHW

Water speed and

heading

VTG

Course over ground

and ground speed

XTE

Cross track error

Output data sentences

Sentence Meaning
DBT (Ver. 1.5)

Depth below

transducer

DPT (Ver. 2.0, Ver.

3.0)

Depth

MTW* Water

temperature

RMB* (Ver. 2.0)

Recommended

minimum

navigation

information

VHW*

Water speed and

heading

TLL* Target

position,

output by [MARK]

key.

*= Available with connection of optional
sensors/navaid

Advertising