Selecting a Site

EdgeIron 4802CF units can be mounted in a standard 19-inch equipment
rack or on a flat surface. Be sure to follow the guidelines below when
choosing a location.

◆ The site should:

•

be at the center of all the devices you want to link and near a
power outlet.

•

be able to maintain its temperature within 0 to 50 °C (32 to
122 °F) and its humidity within 5% to 95%, non-condensing

•

provide adequate space (approximately two inches) on all sides for
proper air flow

•

be accessible for installing, cabling and maintaining the devices

•

allow the status LEDs to be clearly visible

◆ Make sure twisted-pair cable is always routed away from power lines,

fluorescent lighting fixtures and other sources of electrical
interference, such as radios and transmitters.

◆ Make sure that a separate grounded power outlet that provides 100 to

240 VAC, 50 to 60 Hz, is within 2.44 m (8 feet) of each device and is
powered from an independent circuit breaker. As with any equipment,
using a filter or surge suppressor is recommended.