2 monitor unit – Furuno FA-150 User Manual

Page 14

Advertising
background image

8

1.2 Monitor

Unit

The monitor unit can be installed on a desktop or flush mounted in a panel. Install it

on the chart table or near the steering place, referring to the outline drawing.

When selecting a mounting location for the monitor unit, keep the following in mind:

•

Keep the unit out of direct sunlight.

•

The temperature and humidity should be moderate and stable.

(Operating temperature range: -15°C to +55°C)

•

Locate the unit away from exhaust pipes and vents.

•

The mounting location should be well ventilated.

•

Mount the unit where shock and vibration are minimal.

•

Keep the unit away from electromagnetic field generating equipment such as

motor, generator.

•

For maintenance and checking purposes, leave sufficient space at the sides and

rear of the unit and leave slack in cables. Refer to the outline drawing.

•

A magnetic compass will be affected if the unit is placed too close to it. Observe

the following compass safe distances to prevent disturbance to the magnetic

compass:

Standard compass: 0.45 meters

Steering compass: 0.3 meters


Desktop mounting

1. Fasten the hanger with four self-tapping screws (5x20).

2. Fasten the monitor unit to the hanger with two knobs.

Tabletop

Overhead


Flush mounting

There are two types of flush mount kits, F type and S type. For details, see the

outline diagrams at the back of this manual.