Iec 61162-1/2 data sentences – Furuno FA-150 User Manual
Page 34

28
5. IEC 61162-1/2 DATA
SENTENCES
IEC 61162-1/2 format data is input or output from the data port COM1-COM6. The
table below shows the input/output data specifications.
Transponder
Port
Menu setting
Input/Output
Data format
LONG RANGE
Input/Output*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
COM1
EXT DISPLAY
Input/Output*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
COM2 EXT
DISPLAY Input/Output*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
COM3 EXT
DISPLAY Input/Output*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
SENSOR Input*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
COM4
EXT DISPLAY
Input/Output*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
COM5 SENSOR
Input*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
COM6 SENSOR
Input*
IEC61162-2 (38.4kbps) /
IEC61162-1 (4800bps)
AD-10
*: See next page for details.