Technical data, Symbols, Functional description – Festool OF 2200 EB User Manual

Page 8: Use for intended purpose, Electrical connection, Extension cable

Advertising
background image

8

TO REDUCE THE RISK OF

INJURY, USER MUST READ AND UNDER-

STAND INSTRUCTION MANUAL.

Technical data

Power

15 A

Voltage

~ 120 V, 60 Hz

No load speed

10000 - 22000 rpm

Quick height adjustment

80 mm (3.1“)

Fine height adjustment

20 mm (0.8“)

Router diameter, max.

89 mm (3.5")

Drive shaft connection

of the spindle

M 22x1

Weight

7.8 kg (17.2 lbs)

Protection class

/ II

Symbols

V Volts
A Amperes
Hz Hertz
~

Alternating current

n

0

No load speed

Class II Construction

rpm Revolutions or reciprocation per

minute

Ø Diameter

Warning of general danger
Read the Operating Instructions/

Notes!

f

Advice or tip

Functional description

The pictures for the functional description

are on a fold-out page at the beginning of

the instruction manual. When reading of the

manual you can fold out this page for having

always an overview of the machine.
1.1

Adjusting wheel for fi ne routing

depth adjustment

1.2

Dial ring for fi ne routing depth ad-

justment

1.3

Rotary knob for fi xing routing depth

1.4

Scale for routing depth

1.5

Depth stop with indicator

1.6

Clamp lever for depth stop

1.7

Eccenter for connecting depth stop

and stepped stop

1.8 Stepped

stop

1.9

Lever for changing base runner

1.10 Rocker switch for spindle lock
1.11 Adjusting wheel for speed control
2.1

Locking knob for on/off switch

2.2 On/off

switch

2.3

Lever for locking protective guard

2.4 Handles
2.5 Extractor

connector

Use for intended purpose

The routers are designed for routing wood,

plastics and similar materials. Aluminium and

plasterboard can also be processed with cor-

responding cutters such as are listed in the

Festool catalogues.

The user is liable for damag-

es and injuries due to incorrect usage.

Electrical connection

The network voltage must conform to the

voltage indicated on the rating plate. A 16 A

safety fuse (for 120 V) or a corresponding

protective circuit-breaker is required.

Extension cable

If an extension cable is required, it must have

a suffi cient cross-section so as to prevent an

excessive drop in voltage or overheating. An

excessive drop in voltage reduces the output

and can lead to failure of the motor. The table

below shows you the correct cable diameter as

a function of the cable length for the router OF

2200 EB. Use only U.L. and CSA listed exten-

sion cables. Never use two extension cables

together. Instead, use one long one.

Total Extension Cord

Lenght (feed)

25

50

100 150

Cord size (AWG)

16

14

12

10

Note:

The lower the AWG number, the stronger the

cable.