Table 5: Fields, Options and Defaults for the Serial/Parallel Port Configuration Submenu of Advanced Menu

Menu Field

Options

Default

Description

Serial Port:

■

Disabled

■

Enabled

■

Auto

[Enabled]

Configures the serial port using either no configuration (Disabled), a user
defined configuration (Enabled), or by allowing the BIOS or OS to choose
the configuration (Auto).

I/O Address:

■

3F8 - 3FF

■

2F8 - 2FF

■

3E8 - 3EF

■

2E8 - 2EF

[3F8 - 3FF]

Allows user to set the serial port base I/O address when serial port is
Enabled.

Interrupt:

■

IRQ 3

■

IRQ 4

■

IRQ 10

■

IRQ 11

[IRQ 4]

Allows user to set the serial port interrupt when serial port is Enabled.

Infrared Port:

■

Disabled

■

Enabled

■

Auto

[Enabled]

Configures the infrared port using either no configuration (Disabled), a user
defined configuration (Enabled), or by allowing the BIOS or OS to choose
the configuration (Auto).

Mode:

■

IrDA

■

FIR

[FIR]

When the infrared port is enabled this option is available allowing
the user to set the mode for the infrared port.

I/O Address:

■

3F8 - 3FF

■

2F8 - 2FF

■

3E8 - 3EF

■

2E8 - 2EF

[2E8 - 2EF]

Allows user to set the infrared port I/O address when the
infrared port is Enabled.

Interrupt:

■

IRQ 3

■

IRQ 4

■

IRQ 10

■

IRQ 11

[IRQ 3]

Allows user to set the infrared port interrupt when the infrared
port is Enabled.

I/O address:

■

400 - 43F

■

480 - 4BF

■

500 - 53F

■

580 - 5BF

[400 - 43F]

Allows user to set the infrared port I/O address when the
infrared port is Enabled.

DMA Channel:

■

DMA 1

■

DMA 3

[DMA 3]

Allows user to set the infrared port DMA Channel when the
infrared port is Enabled.

Parallel Port:

■

Disabled

■

Enabled

■

Auto

[Enabled]

Configures the parallel port using either no configuration (Disabled), a user
defined configuration (Enabled), or by allowing the BIOS or OS to choose
the configuration (Auto).

Mode:

■

Output

Only

■

Bi-direc-
tional

■

ECP

[Bi-directional]

When the parallel port is enabled this option is available allowing the user
to set the mode for the parallel port. Bi-directional allows two-way transfer
of information between your notebook and a connected parallel device.
Output Only (Half Duplex) allows information to be transferred in only one
direction, from your notebook to the printer or similar device. ECP Mode
allows communication with the ECP class of parallel I/O devices.

I/O address:

■

378 - 37F

■

278 - 27F

■

3BC - 3BF

[378 - 37F]

Allows user to set the parallel port base I/O address when the
parallel port is Enabled.

Interrupt:

■

IRQ 5

■

IRQ 7

[IRQ 7]

Allows user to set the parallel port interrupt when the parallel
port is Enabled.

A d v a n c e d M e n u

Advertising