Figure 7 - Minimum Mantel Clearances When Using Hood

Continued

FLOOR CLEARANCES

A. If installing appliance on the floor level,

you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).

B. If combustible materials are less than

14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).

INSTALLATION

Continued

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Sets

18" & 24" Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(HDABK,HDABR)

Top of Fireplace
Opening

Underside of
Mantel Shelf

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet clearances
listed in Figure 6 you will need a hood.

Determining Minimum Mantel
Clearance

If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).

Determining Minimum Mantel
Clearance When Using a Hood

If minimum clearances in Figure 6 are not met,
you must have a hood. When using a hood
there are still certain minimum mantel clear-
ances required. Follow minimum clearances
shown in Figure 7, page 9 when using hood.

NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

12"

8"

(A)

18"

14"

20"

16

3/4

"

22"

18

1/2

"

24"

20"

All minimum
distances are
in inches

Log Set
24" Models

18" Model

2

1

/2

"

6"

8"

10"

Mantel Shelf

14"
Min.

Combustible
Material

Non-Combustible
Material

Hearth

5"
Min.

Combustible
Material

Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring

14"

Min.

Combustible
Material

Noncombustible Material

Hearth

Combustible
Material

5"
Min.

Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level

24" & 30" Models

All Models

NOTICE: Surface temperatures of
adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch. If
installed properly, these tempera-
tures meet the requirement of the
national product standard. Fol-
low all minimum clearances
shown in this manual.