Installation instructions, Important, Moving the cooker – Fisher & Paykel FREESTANDING COOKER OR120 User Manual

Page 11: Ventilation requirements (gb & ie only)

Advertising
background image

9

Installation instructions

Moving the cooker

Important!

Two people must always raise the cooker, as
shown, to prevent damaging the adjustable
feet.

Do not lift the cooker by the door handles.
DO NOT DRAG the cooker. Lift the feet clear
of the floor.

Ventilation requirements (GB & IE
only)

The appliance should be installed in
a room or space with an air supply in
accordance with BS 5440-2:2000.
For rooms with a volume of less than 5
m

3

: permanent ventilation of 100 mm

3

free area will be required.
For rooms with a volume of between 5
m

3

and 10 m

3

: permanent ventilation

of 50 cm

3

free area will be required

unless the room has a door which opens
directly to the outside air, in which case
no permanent ventilation is required.
For rooms with a volume greater than
10 m

3

: no permanent ventilation is

required.

Note: regardless of room size, all rooms
containing the appliance must have
direct access to the outside air via an
openable window or equivalent.
Where there are other fuel burning
appliances in the same room, BS
5440-2:2000 should be consulted to
determine the correct amount of free
area ventilation requirements.

Fig. 5a Correctly raising the cooker

Fig. 5c Incorrectly raising the cooker

Fig. 5b Incorrectly moving the cooker

Advertising