BURNERS

Nominal

Power

[kW]

Reduced

Power

[kW]

G 30 - 28-30 mbar

G 31 - 37 mbar

G 20

20 mbar

By-pass

[1/100

mm]

Ø injector

[1/100

mm]

By-pass

[1/100

mm]

Ø injector

[1/100

mm]

Semi-rapid 1,75

0,45

32

65

97

(Z)

Triple ring wok

3,50

1,50

65

95

135 (T)

Dual

inner

crown

1,00 (*)

0,32 (*)

27

50

(no. 1

central

69 (F1)

(no. 1

central

outer

crown

4,50 (#)

1,90 (#)

60

66

(no. 2

outer)

102 (Z)

(no. 2

outer)

Fig. 6

Maintenance instructions

Table for the choice of the Injectors Cat: II 2H 3+

Lubrication of the gas taps

A qualified technician must lubricate the gas taps.

Important!

All installation, maintenance and conversion of the appliance must be done using original factory parts.
The manufacturer declines any liability if these correct parts are not used.

GB

IE

(*): Power calculated with inner crown operating.
(#): Power calculated with inner and outer crowns operating.

adjustable