2. System Features

 Power Control
 Fan Control
 Fan Delay Off
 Buzz Control
 Led Display
 Keyboard
 Kettle Detect
 Kettle Empty Detect
 Timing Power Off(3Hours)
 Constant Power Heating
 Constant Temperature Heating
 IGBT Temp Detect
 Plate Temp Detect

 IGBT Temp Higher Protect(120℃)

 Plate Temp Higher Protect(300℃)

 Kettle Empty Protect(300℃)

 Sensor Open/Short Detection
 Over Current Protect(18A)
 Over Voltage Protect(260V)
 Lower Voltage Protect(150V)
 Surge Protect(1000V)
 No Operation for 2 Hours, auto turn off,if no timer

In the system design, we will use some feedback signals to protect system or calculate

watt. The protect signal include over current, over voltage, surge voltage and kettle detect.
Anyone of them appears, the system must stop work. If the IGBT temperature is raise over
60℃, the fan must turn on. If the IGBT temperature is raise over 120℃, the system must stop
work. If the kettle is empty, the plate temp will raise. If the temp raise up to 300℃, the system
must stop work.