USAGE PRECAUTIONS

• Printed circuit board ground lines should be set up with consideration for common impedance.

• Take appropriate static electricity measures.

• Containers for semiconductor materials should have anti-static protection or be made of conductive material.
• After mounting, printed circuit boards should be stored and shipped in conductive bags or containers.
• Work platforms, tools, and instruments should be properly grounded.
• Working personnel should be grounded with resistance of 250 kΩ to 1 MΩ between body and ground.

• Do not apply negative voltages.

• The use of negative voltages below −0.3 V may create parasitic transistors on LSI lines, which can cause

malfunction.

ORDERING INFORMATION

EV BOARD ORDERING INFORMATION

RoHS COMPLIANCE INFORMATION OF LEAD (Pb) FREE VERSION

The LSI products of Fujitsu Microelectronics with “E1” are compliant with RoHS Directive , and has observed
the standard of lead, cadmium, mercury, Hexavalent chromium, polybrominated biphenyls (PBB) , and polybro-
minated diphenyl ethers (PBDE) .

The product that conforms to this standard is added “E1” at the end of the part number.

MARKING FORMAT (Lead Free version)

Part number

Package

Remarks

MB39A104PFV-

❏❏❏E1

24-pin plastic SSOP

(FPT-24P-M03)

Lead Free version

EV board part No.

EV board version No.