FUJITSU MB39A104 User Manual

Page 36

Advertising
background image

MB39A104

36

MB39A104PFV-❏❏❏E1

RECOMMENDED CONDITIONS OF MOISTURE SENSITIVITY LEVEL

[Temperature Profile for FJ Standard IR Reflow]

(1) IR (infrared reflow)

(2) Manual soldering (partial heating method)

Conditions : Temperature 400

°C Max

Times

: 5 s max/pin

Item

Condition

Mounting Method

IR (infrared reflow) , Manual soldering (partial heating method)

Mounting times

2 times

Storage period

Before opening

Please use it within two years after

Manufacture.

From opening to the 2nd

reflow

Less than 8 days

When the storage period after

opening was exceeded

Please processes within 8 days

after baking (125

°C, 24H)

Storage conditions

5

°C to 30 °C, 70%RH or less (the lowest possible humidity)

260

°C

(e)

(d')

(d)

255

°C

170

°C

190

°C

RT

(b)

(a)

(c)

to

Note : Temperature : the top of the package body

(a) Temperature Increase gradient : Average 1

°C/s to 4 °C/s

(b) Preliminary heating

: Temperature 170

°C to 190 °C, 60 s to 180 s

(c) Temperature Increase gradient : Average 1

°C/s to 4 °C/s

(d) Actual heating

: Temperature 260

°C Max; 255 °C or more, 10 s or less

(d’)

: Temperature 230

°C or more, 40 s or less

or

Temperature 225

°C or more, 60 s or less

or

Temperature 220

°C or more, 80 s or less

(e) Cooling

: Natural cooling or forced cooling

H rank : 260

°C Max

Advertising