2 replacing the fuse, 3 troubleshooting, 2 replacing the fuse -2 3.3 troubleshooting -2 – Furuno AIS Transponder FA-50 User Manual

Page 36: Warning

Advertising
background image

3. MAINTENANCE, TROUBLESHOOTING

3-2

3.2

Replacing the Fuse

The fuse (4A) inside the FA-50 protects it from overcurrent and equipment fault. If the
unit cannot be powered, that is, the PWR (power) LED is off, the fuse may have blown.
If this happens, turn off the power to the FA-50, open the body cover and check the
fuse. If the fuse has blown, find out the reason before replacing it. If it blows again after
replacement, contact a FURUNO agent or dealer for advice.

3.3

Troubleshooting

The troubleshooting table below provides typical operating problems and the means
to restore normal operation. If you cannot restore normal operation, do not open the
shield cover; there are no user serviceable parts inside the transponder.

Part

Type

Code No.

Fuse (4A)

FGMB 125V 4A PBF

000-157-482-10

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage to the
equipment and cause fire.

Symptom

Problem

Remedy

Transponder cannot
be powered.

Fuse inside the transponder
may have blown.

Replace the fuse.

Cannot transmit/re-
ceive

• VHF antenna cable connec-

tion may haveloosened.

• Antenna or its cabling may be

damaged.

• Rx channel setting is wrong.

• Check if the cable is firmly

connected.

• Check the antenna and its

cabling for damage.

• Confirm the channel set-

ting.

The message is sent
to wrong ship.

Setting of transmission is not
correct.

Confirm MMSI.

No position data

• GPS antenna may be dam-

aged.

• GPS antenna cable may be

damaged.

• Change the GPS anten-

na.

• Check if the cable is firmly

fastened. If the cable has
damage, change it.

Advertising