PRODUCT FEATURES

opeRAtIoN

This firebox is designed for use with approved
ANSI Z21.11.2 decorative type unvented room
heaters. (Physical size limitations apply. Refer
to minimum firebox requirements supplied
with log heater.) It requires no outside vent-
ing or chimney making installation easy and
inexpensive. When used without the blower,
the firebox requires no electricity making it
ideal for emergency backup heat.

bloWeR AccessoRy

The circulating models will accept either a ro-
tary type fan (model BK) or the triple radial fan
blower system (model BK3) accessories. The
blower circulates heated air from the firebox
into the room. Use of blower is optional.

ReFRActoRy bRIck lINeR

Your firebox may feature a concrete refrac-
tory brick liner. As with all concrete liners,
this liner may develop slight cracks when
exposed to heat. These cracks will not affect
the performance of the fireplace or vent-free
gas logs.

LOCATINg FIREBOX

plANNING

Plan where you will install the firebox. This will
save time and money later when you install
the firebox. Before installation, consider the
following:
1. Where the firebox will be located. Allow for

wall and ceiling clearances (see Installa-
tion Clearances
, page 9).

2. Everything needed to complete installation.

3. These models CANNOT be installed in a

bedroom unless the maximum BTU rating
of the installed vent-free log set is less
than 10,000 Btu/Hr.

4. Proper air for combustion and ventilation

(page 6).