Prepare incoming black iron gas line with

Teflon tape or pipe joint compound (check with

local codes as to the use of Teflon tape). Com-

pounds used on threaded joints of gas piping

shall be resistant to the action of propane/LP

and should be applied lightly to ensure excess

sealant does not enter the gas line.
Complete your gas installation by connecting

the incoming gas line to the appliance regula-

tor. Secure all joints tightly with wrench but do

not overtighten. If a flexible gas line is used,

take care not to kink the connector.

WARNING: All gas piping

and connections must be tested

for leaks after the installation is

completed. After ensuring that

the manual shutoff gas valve is

open, apply a soap and water

solution to all connections and

joints. If bubbles appear, leaks

can be detected and corrected.

DO NOT USE OPEN FLAME FOR

LEAK TESTING AND DO NOT

OPERATE ANY APPLIANCE IF

A LEAK IS DETECTED.

iNSTALLATiON

Continued

GAS SUPPLY TESTING

Note: This section is intended as a guide for

qualified technicians installing gas to this

vent-free firebox.

CAUTION: Do not connect

vent-free heater before pressure

testing gas piping. Damage to

gas valve may result and an un-

safe condition may be caused.

The appliance and its’ individual shutoff valve

must be disconnected from the gas supply

piping system during any pressure testing of

that system at test pressures in excess of 1/2

psig (3.5 kPa).
The appliance must be isolated from the gas

supply piping system by closing manual shut-

off valve during any pressure testing of the gas

supply piping system at test pressures equal

to or less than 1/2 psig (3.5 kPa).

Figure 15 - Locating Electrical

Connection and Gas Connection on

Either Side of Fireplace

HARD-WIRING FIREBOx

Model FBPS and FGPN can be hard-wired

to the duplex outlet located inside the firebox

bottom if desired. This allows the blower ac-

cessory to be plugged into the duplex outlet.

NOTICE: A qualified electrician

must connect electrical wiring to

duplex outlet for built-in instal-

lation. Follow all local codes. In

absence of local codes follow

The National Electric Code ANS/

NFPA 70.

ELECTRICAL INSTALLATION

A model GA3500A blower system assembly

is available for use with the FBPS and FGPN

(-LS) vent-free firebox as an optional acces-

sory. This blower is designed to be installed

on either side of the FBPS and FGPN(-LS)

firebox, when provisions for a 120 VAC sup-

ply connection are made at either end of the

cabinet. Use of a blower system other than

those manufactured by FMI PRODUCTS, LLC

voids the warranty.
Electrical connections are made within the

receptacle with wires that are routed through

the bushing provided (see Figure 15). The re-

ceptacle may be relocated to either side, when

necessary. However, the cover plate must be

replaced over the unused access point. Be

certain to properly ground the vent-free firebox

using the green grounding wire.

Cover

Plates

Electrical

Connection

Access Hole

Gas Connection

Access Hole