Special functions

Clock pr

Clock pr

Clock pr

Clock pr

Clock programming

ogramming

ogramming

ogramming

ogramming

t The clock can be reprogrammed at any time except during an active timed function.

t The clock can be displayed in a twelve hour format and valid clock times are from 1:00 to 12:59.

t The clock can be reprogrammed pressing the “TTTTTimer

imer

imer

imer

imer” button for 5 seconds, and after, the clock can be

adjusted with the “

” and “

” buttons. Colon “:” will flash indicating clock programming mode.

t The user can have minute increments / decrements of 1 minute, but if the user keep pressing the “

”/

” buttons for more than 1 second, the increments / decrements will be of 5 minutes.

During this option the control will round to the nearest 5 minutes.

t The user can finish on reprogramming the clock pressing the “ TTTTTimer

imer

imer

imer

imer” button.

t After 1 minute of no button pressed the control will accept the programmed clock time and will add one

minute to the set clock.

Gr

Gr

Gr

Gr

Grease filter saturation alarm

ease filter saturation alarm

ease filter saturation alarm

ease filter saturation alarm

ease filter saturation alarm

t After thirty fan functional hours, the display will show “ Gr

Gr

Gr

Gr

Gr ease Filter

ease Filter

ease Filter

ease Filter

ease Filter” if the fan is active.

When this icon is shown in the display, the grease filters installed are required to be washed.

t To reset the grease filter saturation alarm the user must press the “

” button for 5 seconds, after this

action the icon “ Gr

Gr

Gr

Gr

Gr ease filter

ease filter

ease filter

ease filter

ease filter” is not displayed, and the hood has the normal display operation.

Char

Char

Char

Char

Charcoal filter saturation alarm (Recir

coal filter saturation alarm (Recir

coal filter saturation alarm (Recir

coal filter saturation alarm (Recir

coal filter saturation alarm (Recirculating accessories)

culating accessories)

culating accessories)

culating accessories)

culating accessories)

t After one hundred and twenty functional hours of the fan, the display will show “ Char

Char

Char

Char

Char coal Filter

coal Filter

coal Filter

coal Filter

coal Filter” if the fan

is active. When this icon flashes on display, the charcoal filters installed are required to be replaced or
reactivated.

t To reset the charcoal filter saturation indication the user must press the “

” button for 5 seconds, after

this time the icon “ Char

Char

Char

Char

Char coal filter

coal filter

coal filter

coal filter

coal filter” is not displayed and the hood has the normal display operation.

Audible signal activation and deactivation

Audible signal activation and deactivation

Audible signal activation and deactivation

Audible signal activation and deactivation

Audible signal activation and deactivation

t The audible signals can be activated or deactivated pressing the “Light

Light

Light

Light

Light” button for 5 seconds.

t If the audible signal is activated, a tone must sound and the “ Snd

Snd

Snd

Snd

Snd” symbol must appear on the display for

2 seconds.

t If the audible signal is deactivated, the “ Snd

Snd

Snd

Snd

Snd” symbol must appear on the display for 2 seconds and no

tone must sound.

Char

Char

Char

Char

Charcoal filter inclusion and exclusion (Recir

coal filter inclusion and exclusion (Recir

coal filter inclusion and exclusion (Recir

coal filter inclusion and exclusion (Recir

coal filter inclusion and exclusion (Recirculating accessories)

culating accessories)

culating accessories)

culating accessories)

culating accessories)

t The charcoal filter inclusion or exclusion can be set by pressing the “

” and “

” buttons at the same

time for 5 seconds.

t The Inclusion or exclusion of charcoal filter must be selected while the lamps and the motor are OFF.

t When the charcoal filter has been excluded, the charcoal filter alarm is disabled.

Heat sensor

Heat sensor

Heat sensor

Heat sensor

Heat sensor

t The control is equipped with a heat sensor that will turn on the blower at second speed if excessive heat

occurs (over 158° F

158° F

158° F

158° F

158° F or 70°C

70°C

70°C

70°C

70°C) surrounding the control area.

t If the blower is OFF or if it is operating at first speed, the blower will be set automatically to second speed,

the display shows the word " CArE

CArE

CArE

CArE

CArE" to indicate that heat sensor has detected an excessive heat.

t During this state, the user may raise the blower speed to third speed but can not decrease the speed.

t When the temperature level on the hood drops to normal, the blower will operate in the setting defined by

the user before the alarm occured.