INSTALLATION

S

MOKE

P

IPE

, T

YPE

“B”

VENTS AND

T

YPE

”L”

VENTS

1. Insert the Type “C” housing directly into the vent pipe. (See Figure 1)

2. Fasten housing to vent pipe using three (3) sheet metal screws, located 120º

apart.

3. Seal joint with a high temperature silicone adhesive sealant

M

ASONRY

C

HIMNEYS

1. Measure the size of the chimney liner and compare this dimension to the

diameter of the base plate on the inducer. Allow for at least ½ inch overlap of

the base plate. If this overlap cannot be maintained, refer to Installation with
Chimney Cap Section.

2. Apply a bead of high temperature silicone adhesive sealant around the

edge of the masonry top or chimney liner.

3. Install the draft inducer on top of the chimney with the unit resting on the

base plate. Make sure the unit is sealed. Fasten the inducer to the chimney
using anchor bolts and securing wires or cables. (See Figure 2)

W

ITH

C

HIMNEY

C

AP

1. Construct a chimney cap that completely covers the outside of the chimney.

(See Figure 3)

2. Apply a bead of high temperature silicone adhesive sealant around the hole

cut in the center of chimney cap. Fasten chimney cap onto draft inducer
base plate with three (3) sheet metal screws.

3. Apply a bead of high temperature silicone adhesive sealant around edge of

the masonry top and fasten chimney cap onto chimney. (See Figure 4)

Figure 1

Figure 2

Figure 3

Figure 4