[ Sweep Timing Adjustment ]

Use omnipad to straighten

target and press ENTER key.

Correction 0.000 nm

<Press MENU for inst setup>

Figure 3-5 Sweep timing adjustment

message

4. Operate the trackball to straighten the tar-

get selected at step 2, and then press the
[ACQ/ENTER] key.

3.6 Adjusting MBS

(Adjustment range: 0.00~0.25)

Main bang, a large filled circle which appears
at the display center on short ranges, can be
suppressed as follows:

1. Transmit on long range about 10 minutes.

2. Adjust the gain to show a small amount

of noise on the display.

3. Change to the 0.125 nautical mile range

and adjust the [A/C SEA] control.

4. Select “11. MBS Adjustment” from the In-

stallation Setup menu and press the
[ACQ/ENTER] key. The following mes-
sage appears:

[MBS Adjustment]

Set value by T-ball

and press ENTER key.

Correction 000

<Press MENU for inst setup>

Figure 3-6 MBS adjustment message

5. Operate the trackball to suppress main

bang (adjustment range: 000 to 025).

6. Press the [ACQ/ENTER] key.

3.7 Selecting STC Curve

The STC curve changes with respect to the
antenna height above the waterline. The de-
fault STC curve can be maintained in most
cases. If necessary the STC curve can be
changed as follows:

1. Select “13. STC Curve” from the Installa-

tion Setup menu and press the [ACQ/EN-
TER] key.

2. Select STC curve desired;

Sharp: The effective range of the [A/C
SEA] control is relatively short.
Std: Between Sharp and Gentle.
Gntl (Gentle): The effective range of
the [A/C SEA] control is relatively long.

3. Press the [ACQ/ENTER] key.

3.8 Setting a Dead Sector

When the scanner is installed at a close dis-
tance in front of the wheelhouse, the radar
should be set not to transmit within that area,
to prevent microwave hazard. The dead sec-
tor area graphic can be turned on/off on the
OTHERS menu.

1. Select “7. Dead Sector” from the Installa-

tion Setup menu and press the [ACQ/EN-
TER] key.

2. Operate the omnipad to enter starting

point of sector (in figures).

3. Press the [ACQ/ENTER] key.

4. Operate the omnipad to enter ending point

of sector (in figures, Max: 270

°

).

5. Press the [ACQ/ENTER] key.

Note: This setting should be done after other
adjustment are finished.

Dead
sector

Figure 3-7 Dead sector