16 send diagnostic command – FUJITSU MCE3130AP User Manual

Page 134

Advertising
background image

4 - 66

C156-E142-02EN

The Sense-Key Specific field format is shown in Table 4.100. Format Progress Indication Bytes is
effective only when Sense key is NOT READY and the SKSV bit is 1. Otherwise, the field is set
with X'00'. This field is defined for the FORMAT UNIT command having the Immed bit of 1.

Table 4.100 Format Progress Indication Bytes

Bit

Byte

7

6

5

4

3

2

1

0

15

SKSV

Reserved

16-17

Progress Indication

Progress Indication indicates the formatting completion rate when the denominator is 655356
(X'10000').

Additional Sense Bytes indicates the detailed error code. For repairs, Additional Sense Bytes is
recommended to be defined.

4.6.16 SEND DIAGNOSTIC command

Table 4.101 SEND DIAGNOSTIC command

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code (1Dh)

1

Logical Unit Number

Reserved

SelfTest

Reserved

Reserved

2

Reserved

3-4

Parameter List Length

5-11

Reserved

The SEND DIAGNOSTIC command instructs diagnostic operation from the host.

When the Self-Test bit is 1, the command executes diagnostics on the data buffer. If an error
occurs, the device responds with Check Condition.

Parameter List Length specifies the data length of diagnostic parameters to be transferred.

The functions and specifications of diagnostic parameters are not open.

Advertising