4.6.15 REQUEST SENSE command

Table 4.94 REQUEST SENSE command

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code (03h)

1

Logical Unit Number

Reserved

2-3

Reserved

4

Allocation Length

5-11

Reserved

The REQUEST SENSE command transfers sense data to the host. Sense data indicates detailed
error information on the command whose error was reported previously. If no error command was
reported, SENSE KEY indicates NO SENSE.

When issuing the REQUEST SENSE command to detect the device status, first issue the TEST
UNIT READY command, then issue REQUEST SENSE.

Allocation Length indicates the length of sense data to be transferred in bytes. If Allocation
Length is 0, the command transfers no data and ends normally.

The sense data format is shown in Table 4.95.

Table 4.95 Request sense data

Bit

Byte

7

6

5

4

3

2

1

0

0

Valid

Error Code (70h or 71h)

1

Reserved (00h)

2

Reserved (0h)

Sense Key

3-6

Information

7

Additional Sense Length (18h)

8-11

Command-Specific Information

12

Additional Sense Code

13

Additional Sense Code Qualifier

14

Reserved (00h)

15-17

Sense-key specific

18-31

Additional Sense Bytes