Preferred 4” Hoods

When you have a 4” (10cm) Hood

Maximum length of 4” diameter metal duct.

Number of 90˚

elbows/bends

Rigid

Thick Wall Flexible Metal

(fully extended)

0

64ft

19.5m

36ft

10.9m

1

54ft

16.5m

31ft

9.4m

2

44ft

13.4m

27ft

8.2m

3

35ft

10.6m

25ft

7.6m

4

27ft

8.2m

23ft

7.0m

Acceptable 2 1⁄2”Hood

When you have a 2 1⁄2” (6cm) Hood

Maximum length of 4” diameter metal duct.

Number of 90˚

elbows/bends

Rigid

Thick Wall Flexible Metal

(fully extended)

0

58ft

17.6m

28ft

8.5m

1

48ft

14.6m

23ft

7.0m

2

38ft

11.5m

19ft

5.7m

3

29ft

8.8m

17ft

5.1m

4

21ft

6.4m

15ft

4.5m

For exhaust systems not covered by the exhaust duct length charts (such as multiple unit
hook-ups, plenums, and power-assist fans), call our Customer Care Center: TOLL FREE 888 9FNP USA
(888 936 7872).