Cooktop & Installation Manual

Model COGB

ENGLISH

13

Pressure Testing

The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 PSIG (3.5 kPa).
This appliance, as well as its individual shut-off valve,
must be disconnected from the gas supply piping
system during any pressure testing of the system at
test pressures in excess of 1/2 PSIG (3.5 kPa).
When checking appliance regulator function, make
certain pressure of natural gas supply is between 6
and 14 inches of water column or, if converted for LP
gas, between 11 and 14 inches.

THE PRESSURE TESTING SHOULD BE
PERFORMED BY MEANS OF THE INJECTOR
THREAD ZONE

014

Figure 14.

Pressure Test Method

• Remove grate and burner cap

• Remove aluminum gas spreader

• Temporarily remove the injectors

• Connect the pressure Test instrument into injector

holder thread zone (M6x0,75)

• Check if the cooktop has the correct pressure

• Fix the injector removed for testing and replace

the parts in the right position.
























Gas test inlet

Thread

Advertising