1) XBO lamps are designed for dc operation only. The dc current may only be varied within the

limits of the current control range. An XBO lamp operates best at rated current; over the life of

the lamp, the current may be increased to its maximum value to compensate for loss of light.
The output of the lamp can be reduced by operating the lamp at minimum current but this does

not prolong the life of the lamp;

2) For safety reasons, XBO lamps should be replaced once they reach the end of their average

lamp life, and not later than 1.25 times their average lamp life. After this time there is an
increased risk of the lamp exploding;

3) The anode (positive cap marked ‘+’) must be on top when the lamp is inserted in the vertical

position. If the anode is incorrectly inserted the arc will be unstable, the bulb will blacken more

quickly and the lamp will prematurely fail;

4) The HT lead from the high voltage terminal of the ignitor, must be connected to the cathode

(negative cap marked ‘-‘). If the lamp is connected with the wrong polarity it will be irreparably
damaged after a very short time.

5) In all circumstances the lamp manufacturers data should be referred to when dealing with

lamps.