Fault finding – FrancisFrancis FX560 User Manual

Page 20

Advertising
background image

7-

Fault Finding

All fault finding must be conducted by a competent person or qualified Electrical Engineer.

Please refer to the following table for the trouble-shooting of Xenon lamps.

Fault

Cause

Remedy

„

Wrong Polarity

„

Lamp incorrectly fitted

„

Faulty wiring

„

Anode (large electrode)

must always be on top in
vertical burning position

„

Check polarity, transpose
connections if necessary

„

Cap overheated

„

Cap temperature above

230°C

„

Faulty contacts

„

Cooling equipment

defective

„

Check terminals, tighten or
renew

„

Check cooling equipment
and replace if necessary

„

Arc unsteady

„

Lamp operated outside

current control range

„

Magnetic stabilisation for

horizontal operation
defective

„

Correct current setting

„

Check magnetic
stabilisation

„

Bulb draws in air

„

Crack in graded seal

caused by overheated cap

„

Maximum cap temperature

230°C

„

Check terminals - tighten

or renew

„

Glass erosion on fused
quartz bulb

„

Lamp operated outside
current control range

„

Lamp service life
exceeded

„

Correct current setting

„

Check meter

„

Electrodes damaged

„

Premature blackening

„

Current ripple too high

„

Auxiliary mirror incorrectly
adjusted

„

Have power supply

inspected

„

Adjust auxiliary mirror

„

Asymmetrical blackening

of lamp (in horizontal
burning position)

„

Lamp operated too long in

same position

„

Turn lamp through 180°

after half service life