APPENDIX 2 DIGITAL INTERFACE

Input sentences

DBT, DPT, GGA, GLL, GNS, HDG, HDT, MWV, RMC, ROT, VTG, ZDA

Output sentences

VBW, VDR, VHW, VLW, VTG

Data reception

Data is received in serial asynchronous form in accordance with the standard referenced in IEC
61162-2.

The following parameters are used:

• Baud rate

Input: 38,400 bps, IEC 61162-2-1, 4800 bps, IEC 61162-1-2
Output: Same as above. Baud rate fixed at 38400 bps for DS-600.

• Data bits: 8 (D7 = 0), Parity: none, Stop bits: 1

Data sentences: Input

Data format is IEC 61162-1 Edition 3 unless noted otherwise.

DBT - Depth below transducer

DPT - Depth

D0 D1 D2 D3 D4 D5 D6 D7

Start
bit

Stop
bit

Data bits

1, 2 Water depth, feet
3, 4 Water depth, m
5, 6 Water depth, fathom

$ ** DBT, x.x, f, x.x, M, x.x, F *hh <CR><LF>
1 2 3 4 5 6

$ ** DPT, x.x, x.x, x.x, *hh <CR><LF>
1 2 3

1. Water depth relative to transducer, in meters
2. Offset from transducer, in meters
3. Maximum range scale in use