Specifications, Electrical, Plumbing – Follett MCC400A/W User Manual

Page 5: Ambient, Electrical connections

Advertising
background image

5

Specifications

Electrical

MCC and C series – 220V 60Hz

5.0 full load amps

E series – 230V 50Hz

5.0 full load amps

Power cord provided on icemaker and dispenser.

Plumbing

3/8" OD push-in water inlet
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
3/8" MPT condenser drain (water-cooled condenser only)

Notes: Slope to drain of 1/4" per foot (6mm per 30.4cm run) with a 1/2" minimum is recommended

Water shut-off recommended within 10 feet (3m), drain to be hard piped and insulated

Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.

Follett recommends installation of an activated carbon filter in icemaker inlet water line

Ambient

Air temp

38˚ C/100˚ F max.

10˚C/50˚F min. (best performance below 27˚C/80˚F)

Water temp

32˚C/90˚F max.

4˚C/40˚F min. (best performance below 21˚C/70˚F)

Water pressure

5 Bar/70 P.S.I max. (482kPa)

.69 Bar/89kPa/10 P.S.I. min.

Electrical connections

Model

Electrical connection

Circuits required

C25FB400A/W, C50FB400A/W

cord provided

220V 60Hz

E25FB400A/W, E50FB400A/W

230V 50Hz

C25CT400A/W, C50CT400A/W

cord provided

220V 60Hz

E25CT400A/W, E50CT400A/W

230V 50Hz

C25CR400A/W, C50CR400A/W

cord provided

220V 60Hz, (2) circuits required

E25CR400A/W, E50CR400A/W

230V 50Hz, (2) circuits required

MCC400A/W used with CVU155N

icemaker and dispenser:

220V 60Hz, (2) circuits required

hard-wiring: Cord and plug

connection provided for

bin

signal

(2) MCC400A/W used with CVU155N

icemakers and dispenser:

220V 60Hz, (3) circuits required

hard-wiring: Cord and plug

connection provided for

bin

signal