FUJITSU AOU18RL User Manual

Page 2

Advertising
background image

CONTENTS

SAFETY PRECAUTIONS .................................... En-1

FEATURES AND FUNCTIONS ........................... En-2

NAME OF PARTS ................................................ En-3

PREPARATION .................................................... En-4

OPERATION ........................................................ En-5

TIMER OPERATION ............................................ En-7

SLEEP TIMER OPERATION ................................ En-8

ADJUSTING THE DIRECTION OF

AIR CIRCULATION .............................................. En-9

SWING OPERATION ......................................... En-10

COIL DRY OPERATION ..................................... En-10

MANUAL AUTO OPERATION .......................... En-10

CLEANING AND CARE ..................................... En-11

TROUBLESHOOTING ....................................... En-13

OPERATING TIPS .............................................. En-14

SAFETY PRECAUTIONS

● Do not attempt to install this air conditioner by yourself.
● This unit contains no user-serviceable parts. Always consult authorized service per-

sonnel for repairs.

● When moving, consult authorized service personnel for disconnection and installa-

tion of the unit.

● Do not become excessively chilled by staying for lengthy periods in the direct cooling

airflow.

● Do not insert fingers or objects into the outlet port or intake grilles.
● Do not start and stop air conditioner operation by disconnecting the power supply

cord and so on.

● Take care not to damage the power supply cord.
● In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-

connect the power supply plug, and consult authorized service personnel.

● If the power supply cord of this appliance is damaged, it should only be replaced by

the authorized service personal, since special purpose tools and specified cord are
required.

● Provide occasional ventilation during use.
● Do not direct air flow at fireplaces or heating apparatus.
● Do not climb on, or place objects on, the air conditioner.
● Do not hang objects from the indoor unit.
● Do not set flower vases or water containers on top of air conditioners.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
● Do not pull power supply cord.
● Turn off power source when not using the unit for extended periods.
● Check the condition of the installation stand for damage.
● Do not place animals or plants in the direct path of the air flow.
● Do not drink the water drained from the air conditioner.
● Do not use in applications involving the storage of foods, plants or animals, precision

equipment, or art works.

● Connection valves become hot during Heating; handle with care.
● Do not apply any heavy pressure to radiator fins.
● Operate only with air filters installed.
● Do not block or cover the intake grille and outlet port.
● Ensure that any electronic equipment is at least one metre away from either the in-

door or outdoor units.

● Avoid installing the air conditioner near a fireplace or other heating apparatus.
● When installing the indoor and outdoor unit, take precautions to prevent access to

infants.

● Do not use inflammable gases near the air conditioner.

DANGER!

CAUTION!

En-1

5

6

4

7

8

OPERATION

TIMER

SUPER QUIET COIL DRY

A

B

C

2

E

9

1

=

3

D

9

3

1

H
I

G

F

Fig. 5

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 7

To facilitate explanation, the accompanying illustra-
tion has been drawn to show all possible indicators;
in actral operation, however, the display will only
show those indicators appropriate to the current op-
eration.

Fig. 6

N

Y

^

[

]

Q

R

K

M
J
O

W

L

S
T

U

P

V

a

b

\

Z

c

X

ESPECIFICACIONES

ALIMENTACIÓN ................................................................................................................................................... 208/230 V~60 Hz

REFRIGERACIÓN

CAPACIDAD ........................................................................................................................................................... 18.000 BTU/h

ENTRADA DE ALIMENTACIÓN ..................................................................................................................................... 1,73 kW

CORRIENTE ......................................................................................................................................................................... 7,7 A

CALEFACCIÓN

CAPACIDAD ........................................................................................................................................................... 21.600 BTU/h

ENTRADA DE ALIMENTACIÓN ..................................................................................................................................... 1,93 kW

CORRIENTE ......................................................................................................................................................................... 8,6 A

FICHE TECHNIQUE

ALIMENTATION .................................................................................................................................................... 208/230 V~60 Hz

REFROIDISSEMENT

PUISSANCE FRIGORIFIQUE ................................................................................................................................ 18.000 BTU/h

PUISSANCE ABSORBÉE ............................................................................................................................................... 1,73 kW

INTENSITÉ .......................................................................................................................................................................... 7,7 A

CHAUFFAGE

PUISSANCE FRIGORIFIQUE ................................................................................................................................ 21.600 BTU/h

PUISSANCE ABSORBÉE ............................................................................................................................................... 1,93 kW

INTENSITE .......................................................................................................................................................................... 8,6 A

SPECIFICATIONS

POWER SUPPLY ................................................................................................................................................... 208/230 V~60 Hz

COOLING

CAPACITY .............................................................................................................................................................. 18,000 BTU/h

INPUT POWER ................................................................................................................................................................1.73 kW

CURRENT ............................................................................................................................................................................. 7.7 A

HEATING

CAPACITY .............................................................................................................................................................. 21,600 BTU/h

INPUT POWER ............................................................................................................................................................... 1.93 kW

CURRENT ............................................................................................................................................................................ 8.6 A

MODEL

INDOOR UNIT

MODÈLE

UNIDAD INTERIOR

MODELO

UNITÉ INTÉRIEURE

OUTDOOR UNIT

UNIDAD EXTERIOR

UNITÉ EXTÉRIEURE

ASU18RL

AOU18RL

TYPE

HEAT & COOL MODEL

TYPE

MODÈLE RÉVERSIBLE

TIPO

MODELO DE REFRIGERACIÓN Y CAlEFACCÓN

05L256_9315255013-01_Cover

2005.12.16, 11:41

2

Advertising
This manual is related to the following products: