Information to be read by IDENTIFY DEVICE command (6 of 6)

*20 Word 89: Time required for SECURITY ERASE UNIT command to complete.

MPG3204AH-E = 0004H: 8 minutes
MPG3307AH-E = 0006H: 12minutes
MPG3409AH-E = 0008H: 16 minutes

*21 Word 93: Hardware reset result. The contents of bits 12-0 of this word shall change only during the

execution of a hardware reset.
Bit 15:

0

Bit 14:

1

Bit 13:

1 = device detected CBLID- above V

IH

(80-conductor cable)

0 = device detected CBLID- below V

IL

(40-conductor cable)

Bit 12-8:

Device 1 hardware reset result. Device 0 shall clear these bits to zero.
Device 1 shall set these bits as follows:
Bit 12:

0 = Reserved

Bit 11:

0 = Device 1 did not assert PDIAG-
1 = Device 1 asserted PDIAG-

Bit 10-9: These bits indicate how Device 1 determined the device number.

00 = Reserved
01 = a jumper was used
10 = the CSEL signal was used
11 = some other method was used or the method is unknown

Bit 8:

1

Bit 7-0:

Device 0 hardware reset result. Device 1 shall clear these bits to zero.
Device 0 shall set these bits as follows:
Bit 7:

0

Bit 6:

0 = Device 0 does not respond when Device 1 is selected
1 = Device 0 responds when Device 1 is selected

Bit 5:

0 = Device 0 did not detect the assertion of DASP-
1 = Device 0 detected the assertion of DASP-

Bit 4:

0 = Device 0 did not detect the assertion of PDIAG-
1 = Device 0 detected the assertion of PDIAG-

Bit 3:

0 = Device 0 failed diagnostics
1 = Device 0 passed diagnostics

Bit 2-1:

These bits indicate how Device 0 determined the device number.
00 = Reserved
01 = a jumper was used
10 = the CSEL signal was used
11 = some other method was used or the method is unknown

Bit 0:

1

*22 Word 94: Automatic Acoustic Management

Bit 15-8:

0

Bit 7-0:

Current automatic acoustic management value