PROBLEM

POSSIBLE CAUSE

SUGGESTED SOLUTION

Ice control material not flowing

1. Bridging of material in hopper.

1. Unplug the spreader harness

and tag out if required. Check
hopper for material and free any
bridged material.

1. Control connector plug is loose.

1. Check plug connection at cab

control.

No power to cab control

2. Blown fuse.

2. Check the SFE 6 amp in-line

fuse. Replace if necessary.

Check power supply for 12 VDC.

(Switch is in ON position indicator
light not lit)

3. Low battery or loose connection.

3. Check vehicle battery

connections.

-

Clean off corrosion

-

Repair or replace damaged
wires

4. Open circuit in wire from battery

to cab control.

4. Repair or replace damaged

wires.

1. Wire harness is damaged or has

an open circuit between cab

1a. Check plug connections at cab

control and spreader.

control and spreader.

1b. Check wire connections at

spreader motor and at vehicle
battery – disconnect motor
leads, turn spreader switch on,
check for voltage at motor
leads.

1c. Repair or replace damaged

wires and connectors

Spreader does not operate
(Indicator light lit)

1d. Check the 30-amp in-line fuse.

Replace if necessary.

Motor shaft should turn.

2. Bearings are seized.

2. Check bearings on spinner

shaft, conveyor, and gearbox.

3. Motor brushes are worn and

prevent motor operation.

3. Remove and inspect both motor

brushes. Replace if worn (Brush
kit 65241).

4. Motor bearings seized.

4. Replace motor if the motor shaft

will not turn.

ON/OFF Control

Some of the solutions on the following page are
complicated. If you are not properly trained or
experienced in electrical or mechanical repairs, take
you spreader to your local outlet for repairs.

TROUBLESHOOTING