Technical specifications p09a and p12a – Friedrich P012A User Manual
Page 9
TECHNICAL SPECIFICATIONS P09A AND P12A
7
Model
Cooling Capacity
BTU/h
Voltage / Hz
Amps
Watts
Dimensions
(W” x H” x D”)
Dehumidification
(Pints/Hour)
Indoor Air
Circulation
(CFM)
Refrigerant
Charge)
(R-22)
Locked
Rotor
Amps
Net
Weight
(lbs.)
Circuit
Rating
Plug Face
(NEMA#)
P09A
8900
115/60
8
923
19.5” x 33.6” x 15.5”
4.2
212
18
40.5
80
125V/15A
5-15P
P12A
11500
115/60
10.5
1280
19.5” x 33.6” x 15.5”
4.2
235
24.7
40.5
86
125V/15A
5-15P
Model
Cooling Capacity
BTU/h
Voltage / Hz
Amps
Watts
Dimensions
(W” x H” x D”)
Dehumidification
(Pints/Hour)
Indoor Air
Circulation
(CFM)
Refrigerant
Charge)
(410 A)
Locked
Rotor
Amps
Net
Weight
(lbs.)
Circuit
Rating
Plug Face
(NEMA#)
P09B
10000
115/60
10.8
1200
19.25” x 33.62” x 15.55”
4.2
224
21.2
50
77.2
125V/15A
5-15P
P12B
12000
115/60
11.5
1300
19.25” x 33.62” x 15.55”
4.2
235
24.7
50
81.6
125V/15A
5-15P