Finisar Single Mode XENPAK Transponder FTLX1461E2 User Manual

Page 3

Advertising
background image

FTLX1461E2 Product Specification – October 2008

© Finisar Corporation – October 2008

Rev B

Page 3

Receive Functions
Reserved
Reserved

O

O

38
39

Reserved For Future Use
Reserved For Future Use

RX LANE 0+
RX LANE 0–

O
O

41
42

Module XAUI Output Lane 0+
Module XAUI Output Lane 0–

RX LANE 1+
RX LANE 1–

O
O

44
45

Module XAUI Output Lane 1+
Module XAUI Output Lane 1–

RX LANE 2+
RX LANE 2–

O
O

47
48

Module XAUI Output Lane 2+
Module XAUI Output Lane 2–

RX LANE 3+
RX LANE 3–

AC-coupled,
Internally biased
differential
XAUI

O
O

50
51

Module XAUI Output Lane 3+
Module XAUI Output Lane 3–

DC Power
GND

0 V DC

1, 2, 3, 33, 34,
35, 36, 37, 40,
43, 46, 49, 52,
53, 54, 57, 60,
63, 66, 69, 70

Ground connection for signal ground
on the module

APS

+1.2 V

7, 8, 28, 29

Input from Adaptive Power Supply

APS SENSE

+1.2 V

27

APS Sense Output. Connected to the
APS input inside transponder.

APS SET

25

Feedback input from APS.
Connected to GND through a 1180Ω
resistor inside the transponder.

3.3 V

+3.3 V DC

5, 6, 30, 31

DC Power Input, +3.3 V DC,
Nominal

5.0 V

+5.0 V DC

4, 32

DC Power Input, +5.0 V DC,
Nominal

Reserved

26

Reserved for APD.

Reserved

13

Reserved.



























Advertising