Electrical ac characteristics – Finisar Single Mode XENPAK Transponder FTLX1461E2 User Manual

Page 6

Advertising
background image

FTLX1461E2 Product Specification – October 2008

© Finisar Corporation – October 2008

Rev B

Page 6

Electrical AC Characteristics

(V

CC5

= 4.75 V to 5.25 V, V

CC3

= 3.14 V to 3.47 V, V

CC aps

= 1.152 V to 1.248 V, T

C

= 0°C to 70°C)

Values

Parameter Symbol

min. typ. max. Unit

XAUI Input AC Characteristics (TXLANE[0..3])
Baud Rate
Ethernet

R

XAUIIN

3.125

Gbit/s

Baud Rate Tolerance

R

TOLXAUI

–100 100 ppm

Differential Input Impedance

Z

INXAUI

80

100

120

Differential Return Loss

1)

|S

11

| 10

dB

Input Differential Skew

2)

t

SKEWIN

75

ps

Jitter Amplitude Tolerance

3)

J

XAUITOL

0.65

UI

p-p

XAUI Output AC Characteristics (RXLANE[0..3])
Baud Rate
Ethernet

R

XAUIOUT

3.125

Gbit/s

Baud Rate Variation

R

XAUIVAR

–100 100 ppm

XAUI Eye Mask (far-end)

According to IEEE 802.3ae

Output Differential Skew

t

SKEWOUT

15

ps

Output Differential Impedance

Z

OUTXAUI

80 100

120 Ω

Differential Output Return Loss

1)

|S

22

| 10

dB

Total Jitter

4)

TJ

XAUI

0.35

UI

Deterministic Jitter

4)

DJ

XAUI

0.37

UI

Power-On Reset AC Characteristics
Power-On Reset and TX_ONOFF
Characteristics

According to XENPAK MSA Issue 3.0, 2002-9-18

MDIO I/O AC Characteristics (MDIO; MDC)
MDIO Data Hold Time

t

HOLD

10

ns

MDIO Data Setup Time

t

SU

10

ns

Delay from MDC Rising Edge to
MDIO Data Change

t

DELAY

300

ns

MDC Clock Rate

ƒ

MAX

2.5

MHz

1)

100 MHz to 2.5 GHz.

2)

At crossing point.

3)

Per IEEE Std 802.3ae.

4)

At near-end, No pre-equalization, 1 UI = 320 ps.