Operational Amplifier Version 1.0

Chapter 2 Amplifier Overview

■ Functions of Bits in OPAMP Control Register (OPCR)


OPAMP Operating Mode Settings

Notes:

While the OPAMP is operating, modifying the settings of RES2, RES1 and RES0 is allowed,

however, do not use the output signal of the OPAMP or execute A/D conversion until OPAMP
output becomes stable.

It is recommended to turn off the operational amplifier before modifying the settings of RES2,

RES1 and RES0.