Furuno 2837S User Manual
Page 18

1. MOUNTING
1-10
Contents of FP03-09820/09830
Name Type
Code
No.
Qty
Remarks
Hanger L
03-163-1111
100-305-141 1
Hanger R
03-163-1112
100-305-181
1
03-163-1113 100-305-191 For
FAR-2137S
Hanger stay
03-163-2071 100-305-371
1
For FAR-2837S
Hole plug
CP-30-HP-13
000-160-074-10
2
Plastic rivet
KB-13 Rivet Black
000-570-276-10
4
Hex. bolt
M6x25
000-162-949-10
4
Hex. bolt
M10x30
000-162-884-10
2
Spring washer
M10
000-864-261
2
Flat washer
M10
000-864-131
2
1. Assemble two hangers and hanger stay with two hex bolts (M10x30), flat washers and
spring washers and cover each hex bolt with hole plug.
2. Fix the above assembly to the mounting location with four hex bolts (M12, dockyard
supply).
3. Fasten the monitor unit to the mounting hanger assembly with four hex bolt (M6x25,
supplied).
4. Cover each hex bolts with panel cover.
5. Cover each holes for hand grip on the hangers with plastic rivet (4 pcs).
Panel cover
Hex bolt (M6x25)
(Torque 7.6Nm)
Hanger (R)
Hanger stay
M12 bolts for fixing (Torque 63.5Nm)
(Dockyard supply)
Hanger (L)
Hex bolt M10x30
(Torque 36.5Nm)
Plastic rivet
Hole plug
Panel cover
To remove this, insert fingernail in groove.
Flat Washer M10
Spring Washer M10
Monitor Unit