1. MOUNTING

1-10

Contents of FP03-09820/09830

Name Type

Code

No.

Qty

Remarks

Hanger L

03-163-1111

100-305-141 1

Hanger R

03-163-1112

100-305-181

1

03-163-1113 100-305-191 For

FAR-2137S

Hanger stay

03-163-2071 100-305-371

1

For FAR-2837S

Hole plug

CP-30-HP-13

000-160-074-10

2

Plastic rivet

KB-13 Rivet Black

000-570-276-10

4

Hex. bolt

M6x25

000-162-949-10

4

Hex. bolt

M10x30

000-162-884-10

2

Spring washer

M10

000-864-261

2

Flat washer

M10

000-864-131

2

1. Assemble two hangers and hanger stay with two hex bolts (M10x30), flat washers and

spring washers and cover each hex bolt with hole plug.

2. Fix the above assembly to the mounting location with four hex bolts (M12, dockyard

supply).

3. Fasten the monitor unit to the mounting hanger assembly with four hex bolt (M6x25,

supplied).

4. Cover each hex bolts with panel cover.
5. Cover each holes for hand grip on the hangers with plastic rivet (4 pcs).

Panel cover

Hex bolt (M6x25)
(Torque 7.6Nm)

Hanger (R)

Hanger stay

M12 bolts for fixing (Torque 63.5Nm)
(Dockyard supply)

Hanger (L)

Hex bolt M10x30
(Torque 36.5Nm)

Plastic rivet

Hole plug

Panel cover

To remove this, insert fingernail in groove.

Flat Washer M10

Spring Washer M10

Monitor Unit